INSTRUCTIONS TO INSTALLER:
S Side and Back Wall Clearance: Unit may be safely installed as near as 2 1/2 inches (6.35 centimeters) from side
walls and 3/4 inch (1.91 centimeters) from back wall.
Notice To Installer: Leave these instructions with the appliance.
Notice To Consumer: Retain these instructions for future reference.
8101P645-60
(03-04-00)
DIMENSIONS
inches cm
A 34-9/16 +
1/16 87.9 + 0.2
B20-3/8+
1/16 51.9 + 0.2
C2-1/8 5.4
D 4-1/4 min. clear 10.8
E 35-5/16 89.7
F 21-1/2 54.6
G3-5/8 7.6
INSTALLATION
INSTRUCTIONS
Radiant Cooktop
Models JEC0530 & JEC0536
403 WEST FOURTH STREET, NORTH D NEWTON, IA 50208
JEC0536
FIVE-ELEMENT RADIANT COOKTOPS
JEC0530
FOUR-ELEMENT RADIANT COOKTOPS
IMPORTANT - SAVE FOR THE LOCAL ELECTRICAL INSPECTOR’S USE
IMPORTANT: Installation should be performed only by an authorized Jenn-Air Service Contractor or other qualified
installer. Read safety precautions in the Use & Care Manual before using this appliance.
(Dimensions shown in both inches and centimeters)
DIMENSIONS
inches cm
A 29-1/16 +
1/16 74.0 + 0.2
B20-3/8+
1/16 51.9 + 0.2
C2-1/8 5.4
D 4-1/4 min. clear 10.8
E 29-15/16 76.0
F 21-1/2 54.6
G3-5/8 7.6
UNITS PROVIDED WITH 1/2² (1.3 cm) I.D. FLEXIBLE CABLE 48² (121.9 cm) LONG WITH 6² (15.2 cm) WIRE LEADS
AT END, FURNISHED AND INSTALLED BY MANUFACTURER (CONNECT TO 240 VOLT ELECTRICAL SERVICE).
NOTE: D” is clearance needed for unit depth measure down from top of countertop. Typical for all units.
D
IMPORTANT
CUTOUT
DIMENSIONS ARE
CRITICAL
FIGURE 1
FIGURE 2
Vista de pagina 0
1 2 3 4 5 6

Indice de contenidos

Pagina 1 - Radiant Cooktop

INSTRUCTIONS TO INSTALLER:S Side and Back Wall Clearance: Unit may be safely installed as near as 2 1/2 inches (6.35 centimeters) from sidewalls and 3

Pagina 2 - RECOMMENDED MINIMUM

2Installing Cabinetry Over Your CooktopA= 30²²²² (76.2 cm) minimumclearance between the top ofthe cooktop and the bottom ofan unprotected wood or meta

Pagina 3 - DE INSTALACIÓN

INSTRUCCIONES PARA EL INSTALADOR:S Espacio libre lateral y posterior: La unidad puede instalarse con seguridad tan cerca como 2 1/2 pulgadas (6,35cent

Pagina 4

2Instalación de los gabinetes por encima de lasuperficie para cocinarA=30²²²² (76.2 cm) de espacio libremínimo entre la parte s uperior dela superfici

Pagina 5 - IMPORTANT

INSTRUCTIONS À L’INTENTION DE L’INSTALLATEUR :S Dégagement latéral et arrière: L’appareil peut être installé sans risque aussi près que 2 l/2 pouces (

Pagina 6 - ATTENTION

2Pose d’armoires au-dessus de votre plaque decuissonA = Dégagement minimum de 30 po(76,2 cm) entre le dessus de laplaque de cuisson et le dess ousd’un